JCB logo
Avanti Polar Lipids, Inc.
  Home | Help | Feedback | Subscriptions | Archive | Search | Table of Contents

This Article
Right arrow Full Text (PDF, 1309K)
Right arrow Alert me when this article is cited
Right arrow Citation Map
Services
Right arrow Email this article
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new content in the JCB
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via CrossRef
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Weibel, E. R.
Right arrow Articles by Knight, B. W.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Weibel, E. R.
Right arrow Articles by Knight, B. W.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Facebook   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?
The Journal of Cell Biology, Vol 21, 367-384, Copyright © 1964 by Rockefeller University Press

ARTICLE

A MORPHOMETRIC STUDY ON THE THICKNESS OF THE PULMONARY AIR-BLOOD BARRIER



Ewald R. Weibel M.D.1 and Bruce W. Knight 1

1 From The Rockefeller Institute.

Dr. Weibel's present address is Anatomisches Institut der Universität, Zurich, Switzerland

A reliable knowledge of the thickness of the alveolo-capillary "membrane" or air-blood barrier is of physiologic interest since it is intimately related to a quantitative estimation of such functional events as gas diffusion or tissue metabolism in the lung. The characteristic thickness of the air-blood barrier with respect to gas diffusion is its harmonic mean thickness, while the arithmetic mean thickness is related to the mass of tissue building the barrier and consuming oxygen in the lung. Two morphometric methods are proposed by which these two dimensions can be estimated from random measurements in the electron microscope in a reliable, simple, and efficient manner. By applying these methods to three rat lungs the arithmetic mean thickness of the barrier was found to measure 1.25 µ, the harmonic mean thickness, 0.57 µ. On the basis of these measurements a geometric model of the barrier in the form of a corrugated membrane was derived. Its dimensions showed close similarity to those of the natural barrier. This analysis suggested furthermore that the gas conductance of the barrier is nearly optimal if one considers the mass of tissue and the minimal barrier thickness as fixed properties which are determined by other functional requirements on the alveolo-capillary membrane.

Submitted on July 23, 1963


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Facebook Facebook   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter    What's this?


This article has been cited by other articles:



  Home | Help | Feedback | Subscriptions | Archive | Search | Table of Contents