|
||
© The Rockefeller University Press,
0021-9525/2000//719 $5.00
The Journal of Cell Biology, Volume 149, Number 3,
, 2000 719-730
Original Article |
Direct Observation of Membrane Tethers Formed during Neutrophil Attachment to Platelets or P-Selectin under Physiological Flow
sld{at}seas.upenn.edu
Adhesion and subsequent aggregation between neutrophils and platelets is dependent upon the initial binding of P-selectin on activated platelets to P-selectin glycoprotein ligand 1 (PSGL-1) on the microvilli of neutrophils. High speed, high resolution videomicroscopy of flowing neutrophils interacting with spread platelets demonstrated that thin membrane tethers were pulled from neutrophils in 32 ± 4% of the interactions. After capture by spread platelets, neutrophil membrane tethers (length of 5.9 ± 4.1 µm, n = 63) were pulled at an average rate of 6–40 µm/s as the wall shear rate was increased from 100–250 s–1. The average tether lifetime decreased significantly (P < 0.001) from 630 to 133 ms as the shear rate was increased from 100 s–1 (Fbond = 86 pN) to 250 s–1 (Fbond = 172 pN), which is consistent with P-selectin/PSGL-1 bond dynamics under stress. Tether formation was blocked by antibodies against P-selectin or PSGL-1, but not by anti-CD18 antibodies. During neutrophil rolling on P-selectin at 150 s–1, thin membrane tethers were also pulled from the neutrophils. The characteristic jerking motion of the neutrophil coexisted with tether growth (8.9 ± 8.8 µm long), whereas tether breakage (average lifetime of 3.79 ± 3.32 s) caused an acute jump in the rolling velocity, proving multiple bonding in the cell surface and the tether surface contact area. Extremely long membrane tethers (>40 µm) were sometimes pulled, which detached in a flow-dependent mechanism of microparticle formation. Membrane tethers were also formed when neutrophils were perfused over platelet monolayers. These results are the first visualization of the often hypothesized tethers that shield the P-selectin/PSGL-1 bond from force loading to regulate neutrophil rolling during inflammation and thrombosis.
Key Words: thrombosis P-selectin PSGL-1 hemodynamics tether
© 2000 The Rockefeller University Press
| Introduction |
|---|
|
|
|---|
12,000 molecules/cell) with P-selectin glycoprotein ligand 1 (PSGL-1;
104 molecules/cell) located on the tips of neutrophil microvilli (Moore et al. 1995; Bruehl et al. 1997). Under hemodynamic conditions, the rolling and arrest of neutrophils on spread platelets or activated endothelium involves the transition from P-selectin–mediated tethering to more stable β2-integrin bonding (Lawrence and Springer 1991; Buttrum et al. 1993; Diacovo et al. 1996; Yeo et al. 1994; Weber and Springer 1997). The mechanics and kinetics of the P-selectin/PSGL-1 bond that regulate the adhesive dynamics have been studied using several different experimental techniques. Parallel-plate flow assays have employed flowing neutrophils over monolayers of adherent platelets (Hamburger and McEver 1990; Yeo et al. 1994; Lalor and Nash 1995; Diacovo et al. 1996), sparse islands of platelets (Bahara and Nash 1998), and P-selectin–coated surfaces (Lawrence and Springer 1991; Alon et al. 1995). The P-selectin/PSGL-1 bond displays a modest increase in dissociation when force loaded, with an unstressed off rate koff0= 1–2.4 s–1 and a stressed off rate of 3.5–6.3 s–1 at a wall shear stress of 1 dyne/cm2 (bond loading of 110 pN; Alon et al. 1995; Smith et al. 1999). Plasmon resonance measurements of the affinity and kinetics of the bond between soluble monomeric human P-selectin and immobilized PSGL-1 from human neutrophils yielded values of kon0 = 4.4 x 106 M–1 s–1, koff0 = 1.4 s–1, and Kd = 320 nM (Mehta et al. 1998). In contrast, atomic force microscopy measurements of single complexes between a PSGL-1/IgG chimera immobilized on the tip of an atomic force microscopy cantilever with a surface coated with P-selectin/IgG chimera (Fritz et al. 1998) displayed higher avidity (Kd = 60 nM) than the native P-selectin/PSGL-1 bond (Kd = 320 nM), and resulted in off rates from 0.02 s–1 under zero force up to 15 s–1 under applied forces.
Proposed mechanisms of neutrophil detachment during rolling and adhesion under fluid shear forces involve the following: (1) the dissociation of the receptor bond (Alon et al. 1995); (2) the extraction of membrane receptors (Evans et al. 1991; Shao and Hochmuth 1999); and/or (3) the failure of the membrane. Of these mechanisms, force-induced bond dissociation is the favored model of cell detachment. Microvilli rheology may also have a role during neutrophil rolling (Shao et al. 1998; Chen and Springer 1999). Shao and Hochmuth 1996 using micropipette manipulation and antibody-coated beads demonstrated that microvilli on neutrophils, under a pulling force, can be extended (microvillus extension, 1 µm) or can form long thin membrane cylinders (tether formation, up to 20 µm) depending on the magnitude of the force (Shao et al. 1998). Although these measurements were made under nonphysiological conditions, it is predicted that tether formation could also occur as a result of a bond between PSGL-1 on the neutrophil microvilli and platelet (or endothelial) P-selectin under physiological hemodynamic conditions. Similarly, recent work by Chen and Springer 1999 supports the role for microvilli extension during rolling adhesion by demonstrating neutrophil recoil upon sudden flow deceleration, while Alon et al. 1997 detected a moment arm upon flow reversal; both observations are suggestive of a tether structure.
In this study, we investigated the initial adhesive interactions between neutrophils and platelets using high speed, high resolution differential interference contrast (DIC) videomicroscopy. Under physiological flow conditions, we found that when flowing neutrophils collided with immobilized platelets or rolled on P-selectin–coated surfaces, membrane tethers were pulled from the neutrophil surface. These results are the first reported direct visualization of such tethers forming under venous flow conditions, and may have significant implications in the understanding of bond loading and neutrophil rolling dynamics.
| Materials and Methods |
|---|
|
|
|---|
Neutrophil Isolation
Venous human blood for neutrophil isolation was obtained from healthy donors by venipuncture and anticoagulated with EDTA (nine parts blood to one part K3EDTA). Neutrophils were isolated by centrifugation over neutrophil isolation medium (Cardinal Associates). After isolation, neutrophils were resuspended in either a Mg2+-free Hepes-buffered Tyrode's solution, pH 7.35, containing BSA (3.5 mg/ml), 137 mM NaCl, 2.7 mM KCl, 3.8 mM NaH2PO4, 3.8 mM Hepes, 2 mM CaCl2, and 5.5 mM glucose or in Mg2+-free Hank's balanced salt solution (HBSS; Gibco Laboratories) supplemented with 2% HSA and 2 mM CaCl2, pH 7.4. Immediately after suspension in buffer, cells were counted electronically by a Coulter counter (model Z2) and used in the flow experiments at 105 cells/ml. All subsequent procedures were performed at room temperature.
Microcapillary Flow Chambers
Flow chambers were constructed with rectangular glass capillaries (microcapillary; VitroCom) with a cross-section of 0.2 x 2.0 mm and a wall thickness of 0.15 mm. Microcapillaries were cleaned by overnight incubation in 20% nitric acid, followed by extensive washing with deionized water. The microcapillaries were rinsed with 100% dry ethanol and dried under argon. The ends of the clean microcapillary (length = 7 cm) were inserted into silastic tubing (I.D. 1.47 mm x OD 1.96 mm) and a hermetic seal between the glass capillary and the silastic tubing was established by covering the joint with adhesive lined, heat shrinkable tubing (3M Electronics).
Fibrinogen and P-selectin–coated Surfaces
To promote platelet adhesion, the clean microcapillary flow chambers were incubated with a human fibrinogen solution (100 µg/ml; Enzyme Research Labs) for 1 h at room temperature. After incubation, each flow chamber was washed of excess fibrinogen solution by perfusing Ca2+- and Mg2+-free HBSS containing HSA for at least 20 min. Human platelets were sparsely adsorbed on the fibrinogen before binding studies with neutrophils. In some experiments, monolayers of platelets were prepared by perfusing washed platelets into the chamber and allowing them to settle for at least 30 min. P-selectin–coated surfaces were prepared by incubating clean microcapillary flow chambers with affinity-purified human platelet P-selectin (
1 µg/ml final concentration) in Ca2+- and Mg2+-free HBSS for at least 3 h at room temperature. The flow chamber was washed by perfusing Ca2+- and Mg2+-free HBSS containing 2% HSA through the chamber for at least 30 min, to remove any excess or unbound protein. For site density determinations, clean microcapillary chambers were incubated with the dilute P-selectin solution for 3 h, followed by washing/blocking with the 2% HSA/HBSS for 30 min. The glass microcapillaries were incubated with a solution of 125I-labeled anti–P-selectin antibody clone G1 (3.95 x 106 cpm/µg; Ancell) and diluted in 1% BSA/PBS. After antibody incubation, the tubes were washed with PBS, crushed, and counted in triplicate with a gamma counter.
Cell Treatments
For blocking P-selectin on the surface of platelets, flow chambers coated with platelets were filled with mAb G1 at 20 µg/ml and incubated at room temperature for 20 min before perfusion of neutrophils. To block bonding via PSGL-1 or β2-integrins, neutrophils were incubated with either 20 µg/ml mAb PL1 (anti–PSGL-1) or 20 µg/ml mAb IB4 (anti-CD18) in 2% HSA/HBSS medium containing 2 mM Ca2+ for 30 min before perfusion. The neutrophil suspension was diluted in a 3–10-fold volume of HSA/HBSS medium and immediately perfused into the flow chamber. Energy-depleted neutrophils were prepared by incubating isolated neutrophils with 30 mM sodium azide for 30 min at room temperature before perfusion.
High Resolution, High Speed Imaging under Flow
The flow chamber was mounted on a Zeiss Axiovert 135 microscope. DIC microscopy was conducted with a 63x (NA 1.40) oil immersion objective lens (Plan-Apochromate) and an oil immersion condenser (NA 1.4). During perfusion, neutrophils were withdrawn from a reservoir through the flow chamber at controlled flow rates by a syringe pump (Harvard Apparatus). The wall shear stress imposed on the surface was calculated from the equation
w = (6Qµ)/(B2W), which is the solution of the Navier-Stokes equation for laminar flow of a Newtonian liquid between parallel plates, where
w represents the wall shear stress (dynes/cm2), Q represents the flow rate (cm3/s), µ represents the viscosity (0.01 Poise at room temperature), B represents the total plate separation (0.02 cm), and W represents the width (0.2 cm). The wall shear rate,
w (s–1), was calculated as
w = 6Q/(B2W). Distortions in the flow field, because of the sidewalls, were minimal for the 1:10 aspect ratio of the gap separation to the chamber width and for the imaging of events only in the middle of the chamber away from the sidewalls. Digital images were captured with a high speed digital camera (MotionCorder Analyzer; Eastman Kodak Co.) at imaging rates of 30–240 frames per second (fps). Images from the high speed camera were played back at slow motion (5 fps) or frame-by-frame and recorded on videotape. Control of the videotape recorder was performed using LabVIEW and IMAQ Vision Software (National Instruments) with serial communication to a Pentium-based workstation, while images were digitized via an on-board capture card (model PCI-IMAQ 1408; National Instruments). During video playback, some images were contrast enhanced with background subtraction and grey scale stretching using an Argus 20 Image Processor (Hamamatsu Corp.).
Analysis of Neutrophil–Platelet Interactions
When unstimulated neutrophils were perfused over spread platelet singlets, three general types of interaction occurred: (type 1) membrane tether formation during neutrophil translation downstream without rotation (see Fig. 1 a); (type 2) neutrophil rolling over the platelet without observable membrane tether formation and with an observed neutrophil rotation; or (type 3) pausing without an observable membrane tether formation or rolling. Type 1 interactions were analyzed by determination of cell center positions in successive video frames from the digitized images using Scion Image software. The position of the cell center was determined within one pixel accuracy (± 0.09 µm/pixel) at each instant. During type 1 events, these tethers were extremely thin and short-lived, and often crossed the focal plane of the DIC image. Thus, the growing tethers were sometimes difficult to completely visualize in the image plane because manual refocusing was not possible in real-time during the adhesive events. However, when the microscope was readjusted to the correct focal plane, tethers could be directly and definitively visualized.
|
| Results |
|---|
|
|
|---|
For the neutrophils that formed tethers, determination of the cell center position with time demonstrated the rapid approach velocity of a neutrophil in a streamline above the platelet, the extremely rapid deceleration during capture by the platelet, tether extension, and the acute release of the neutrophil into a streamline closer to the surface (Fig. 2). In Fig. 2 a, the cellular motion of the collision event imaged in Fig. 1 b demonstrated that the upstream velocity of neutrophil was uniform before the adhesive event, whereas the downstream velocity after detachment was markedly slower but almost instantaneously obtained after release. Fig. 2 b shows the distance traveled by the neutrophil as it approached the spread platelet, as a membrane tether grew, and finally as the tether detached from the stationary platelet, and the neutrophil translated downstream (with observable rotation of surface features). The slopes of the lines drawn in Fig. 2 b represent the average velocity of each of these stages, and they demonstrate the distinct transitions between each phase of approach, tether growth, and release.
|
w = 0.5–3.0 dyne/cm2) were investigated by varying the flow rate of the perfusion solution through the chamber. The average tether growth rate increased significantly (P < 0.001) from 6 to 40 µm/s as the wall shear rate was increased from 100 to 250 s–1 (Fig. 3 a), whereas the average time of tether duration decreased significantly (P < 0.001) from 630 to 133 ms with an increasing wall shear rate (Fig. 3 b). Although the average tether length appeared to go through a maximum at 200 s–1 (Fig. 3 c), these values were not statistically different with the overall average tether length being 5.9 ± 4.1 µm (range 1–25 µm, n = 63 tethers). At wall shear rates below 50 s–1 and above 300 s–1, transient tethers were not detected.
|
0.2–0.3 µm. The gap distance of the approaching neutrophils captured by adherent platelets increased modestly from 0.7 to 1.7 µm, with an increasing shear rate from 100 to 250 s–1, an observation that may relate to the frequency of surface encounter of the longest neutrophil microvilli or to very subtle lift forces that may exist (particle Reynolds number,
0.02).
|
µRh
wC), where µ represents the viscosity, R represents the cell radius, h represents the distance from the center of the cell to the wall,
w represents the wall shear rate, and C represents a numerical factor that depends on h/R. The relationship between the force on the cell and the force on the tethered bond was based upon a force balance Fbcos
= Fs. The force on the tether bond can be estimated by visualizing the projected length of the tether (
) and making the following assumptions that: (1) the tether began at the edge of the platelet (point q); (2) the gap distance between the wall and the neutrophil was the height of the neutrophil after release (g
0.3 µm); and (3) the tether originated from the neutrophil at point r. Values for d and h were estimated from the height determined from the neutrophil's approach and release velocities using the method of Goldman et al. 1967. Since the ratio of the tether growth velocity (vtether) to the cellular free flowing velocity (vflow) is typically below 1:20, the assumption of mechanical equilibrium is sufficiently accurate since the shear force is overestimated by <5% for a correction factor of 1–vtether/vflow
0.95. As the first available estimate of the P-selectin/PSGL-1 bond strength where both receptors reside in their natural cellular membranes, the force on the bond increased from 86 to 172 pN as the shear rate increased from 100 to 250 s–1 (Fig. 4 d).
Tether Formation Frequency and Antibody Blocking Experiments
The percentage of initial adhesive events between flowing neutrophils and immobilized platelets, which resulted in the formation of elongated membrane tethers, as compared with transient pausing or rolling is shown in Fig. 5. At a shear rate of 200 s–1, 43 out of 139 collisions observed between free-flowing neutrophils and immobilized platelets resulted in a membrane tether (n = 3 experiments with individual donors). To determine if the observed tether formation was due to P-selectin/PSGL-1 bonding, we studied platelet–neutrophil interactions in the presence of function-blocking mAbs to P-selectin and PSGL-1. Incubating adherent platelets with mAb G1, which binds to an epitope in the lectin domain of P-selectin and blocks binding of P-selectin to leukocytes (Hamburger and McEver 1990) and PSGL-1 (Moore et al. 1995), completely blocked tether formation (Fig. 5). Similarly, incubation of neutrophils with the mAb PL1, which binds to the NH2-terminal region of PSGL-1 and blocks P-selectin binding to this region (Moore et al. 1995), also resulted in the total inhibition of tether formation (Fig. 5). In contrast, incubation of neutrophils with either mAb IB4 against CD18 or with 30 mM sodium azide (NaN3) had no effect on tether formation (Fig. 5).
|
|
10 sites/µm2, n = 3) at a wall shear rate of 150 s–1, they rolled over the surface and formed thin membrane tethers similar to those observed with platelets (Fig. 7 a). The neutrophil displayed a jerky motion of stops and starts as it rolled on the P-selectin surface concomitant with the growth of a membrane tether bonded to the surface. On purified P-selectin, distinct pauses in the neutrophil motion were detected (Fig. 7 c), the majority of which were <1 s, which is consistent with the known lifetime of the P-selectin/PSGL-1 bond. In many recordings, the breaking of the tether occurred at the terminal site of attachment with the surface, and the tether rapidly snapped back to the neutrophil (Fig. 7 a, t = 3.967 s). At the instant that the tether was released from the surface, the neutrophil experienced a sudden rotation forward that was driven by the shear forces (Fig. 7b and Fig. c). To test whether β2-integrins were involved in the formation of these long-lived tethers, neutrophils were treated with mAb IB4 against CD18. Blockade of CD18 did not alter the ability of neutrophils to form tethers on P-selectin–coated surfaces (data not shown). Clearly, P-selectin/PGSL-1 bonds were being formed and broken at the cell-surface contact area to cause pausing, as well as at the end of the tether to cause leaps forward when the tether was released. The force loading is difficult to model because of an uncertainty in contact area loading and bonding in the presence of a tether, which could also be multiply bonded to the surface (Fig. 8). The average tether length observed was 8.9 ± 8.8 µm (n = 31), average tether duration was 3.79 ± 3.32 s (n = 29), and the average tether growth rate was 1.7 ± 0.9 µm/s (n = 29). In contrast to tethering with platelets, where the neutrophil was translating
0.3 µm above the surface, the neutrophil is attached to the surface by P-selectin bond(s) in the contact area as well as by bond(s) of the tether with the surface. This accounts for the long tether lifetime and slow tether growth rate observed with P-selectin–coated surfaces.
|
|
Tether Dragging, Multiple Tethering, Tether Beading, and Neutrophil String Formation on P-selectin
One unique feature of these tethers was, at times when the tether detached from the surface, it did not always snap back fully to the neutrophil body, but would drag along the surface and become reattached similar to the function of a grapple hook to bring the cell to arrest (data not shown). In addition, two or three elongated tethers that were pulled from a single neutrophil were occasionally observed (data not shown). Although most tethers snapped back, inspection of the P-selectin–coated surface after neutrophils rolled on the surface demonstrated the existence of detached tethers that often had a beaded appearance (Fig. 9 a). This is a flow-dependent mechanism of neutrophil microparticle formation and an example of cellular detachment by the failure of the membrane in which receptors are embedded. Fig. 9 b, which shows a single tether that was greater than four fields of view (>100 µm), illustrates that these tethers could grow to be extremely long, and demonstrated the tremendous excess of neutrophil membrane that can supply tether growth. Finally, it was observed that free-flowing neutrophils interacted and rolled on these deposited and beaded tethers, possibly through L-selectin/PSGL-1 interactions (Fig. 9 c).
|
| Discussion |
|---|
|
|
|---|
In this study, we investigated the initial interactions between neutrophils and platelets and report the first direct observation of the formation of elongated membrane tethers by neutrophils under physiological flow conditions. Elongated tethers were pulled from the neutrophil surface when free-flowing neutrophils were captured by spread platelets and when neutrophils rolled on P-selectin–coated surfaces. Tethering was completely blocked with mAbs against P-selectin and PSGL-1, whereas the mAb against CD18 had no effect. These observations extend the following recent measurements of: tether growth between neutrophils and beads coated with antibody using micropipette aspiration (Shao et al. 1998); moment arms of attached neutrophils in reversing flow (Alon et al. 1997); and neutrophil recoil in rapidly decelerated flow (Chen and Springer 1999). Direct observation of the formation of these tethers under physiological flow was made achievable by using high speed, high resolution microscopy, a technique that makes it possible to directly observe cellular events with characteristic times as short as
2 ms and length scales of
100 nm.
In agreement with previous studies, the molecular bond responsible for the initial attachment and tethering of flowing neutrophils to platelets was the P-selectin/PSGL-1 interaction. This fact was demonstrated by the tethering being completely abolished after preincubation of platelets with anti–P-selectin or neutrophils with anti–PSGL-1, whereas incubation of neutrophils with anti-CD18 had no effect (Fig. 5). Similarly, preincubation of neutrophils with the metabolic inhibitor sodium azide, to prevent neutrophil activation during neutrophil–platelet interactions, also did not prevent tether formation, demonstrating that cell activation was not required. These observations, in conjunction with the tethers displaying lifetimes and strengths that are the signature of the P-selectin/PSGL-1 bond (Fig. 3 b and 4 d) and the reproduction of tethering in a purified system with P-selectin–coated surfaces, provide confirmation of the molecular mechanism of tether attachment.
Since cell–cell attachment depends on the balance between the dispersive hydrodynamic forces and the adhesive forces generated by the interactions between membrane bound receptors and their ligands, the effect of shear on tether formation was investigated. Both the tether growth rate and the lifetime of the tether were functions of the wall shear rate, while the average tether length of
6 µm appeared as a plateau between 100 s–1 <
w < 250 s–1. Transient membrane tethers were not observed at shear rates
50 or
300 s–1. During neutrophil tethering to adherent platelets, shear forces generated at a shear rate of 50 s–1 appeared insufficient to pull membrane tethers fast enough or long enough to be observed in our system, which could only resolve membrane tethers that were pulled beyond the cell's diameter (as opposed to microvilli extension). At a shear rate of 300 s–1, the frequency of neutrophil capture was extremely low, and the force loading of the tether likely caused bond breakage before tethers could grow to an observable length beyond the cell's diameter.
The lack of observable membrane tethering below 50 s–1 or above 300 s–1 in our system is consistent with observations of Shao et al. 1998, Alon et al. 1997, and Chen and Springer 1999. Shao et al. 1998 estimated microvilli lengths between 0.35 and 1.0 µm at a shear rate of 22 s–1 (0.22 dyne/cm2) since, at forces <45 pN, microvilli become extended but do not form tethers. Alon et al. 1997 detected lever arms between 2 and 4 µm corresponding to a tether length of 1.0 ± 0.32 µm at reversing flows of 0.3–0.8 dyne/cm2 (
w
30–80 s–1) during neutrophil rolling on P-selectin. For neutrophil rolling on E-selectin at a high wall shear stress of 16 dyne/cm2 (
w
1,600 s–1), Chen and Springer observed neutrophil pull back of 1.4 µm upon instantaneous reduction of flow to 1 dyne/cm2. Given these limits at low and high flow, the observed average tether length of
6 µm in our study (Fig. 4 c) for shear rates between 100 and 250 s–1 represented a plateau to suggest that membrane tethering is most operative in this narrow range of shear rates.
After neutrophil tether breakage, the flowing neutrophil traveled in a plane closer to the wall. The height above the wall and the shear force on the cell, Fs were estimated at each wall shear stress using the results of Goldman et al. 1967. By assuming a single bond at the end of the fully grown tether and using the experimentally determined tether lengths (
), we estimated the force on the bond to be Fb = 86 pN at
w = 100 s–1 (average bond life of 630 ± 380 ms, n = 9) and Fb = 172 pN at
w = 250 s–1 (average bond life of 133 ± 51 ms, n = 10). These bond strengths and lifetimes represent the first such estimates for the platelet P-selectin and neutrophil PSGL-1 bond pair, under conditions where the receptors reside in their respective cellular membranes with a definitive single point attachment between the two cells, and a direct measurement of the length of the lever arm for the force analysis.
Our observation that
32% of neutrophils interacting with platelets formed tethers agrees with Shao's suggestion (Shao et al. 1998) that there may be heterogeneity in the association of the PSGL-1 ligand with the cytoskeleton. Shao et al. 1998 observed two different kinds of behavior, microvillus extension or tether formation, when a given force was applied to the microvilli of the neutrophil. The fact that the same force can result in two types of behavior suggests that they depend on their membrane–cytoskeleton association strength. Microvilli with a strong association between membrane and cytoskeleton can only be stretched a short distance (
1–2 µm), whereas microvilli with a weak association can be pulled out to form tethers. The average force required to extract an integral glycoprotein from the lipid bilayer of a cell has been estimated to be 100 pN (Bell 1978). However, Evans et al. 1991 measured a force of 10–20 pN for glycophorin A extraction from a red cell membrane, whereas Shao and Hochmuth 1999 measured the forces of 25–45 pN for L-selectin extraction, 60–130 pN for β2 integrin extraction, and 35–85 pN for CD45 extraction from neutrophils. However, this was a slow process requiring 1–2 s for L-selectin, 1–4 s for β2 integrin, and 1–11 s for CD45 extraction. For tethering events that lasted under 1 s, we measured bond forces of >60 pN. This appears to agree with Shao (Shao et al. 1998; Shao and Hochmuth 1999) and Alon et al. 1995 who have hypothesized that the cytoplasmic domains of selectins and their counterreceptors, in this case PSGL-1, help anchor these molecules to the cytoskeleton so that they can resist extraction.
When neutrophils interacted with surfaces coated with P-selectin under laminar flow conditions, they rolled with a characteristic jerky motion while forming observable membrane tethers to the surface. Thus, neutrophil PSGL-1 bonding with P-selectin can facilitate the formation of membrane tethers under venous flow conditions. In contrast to the tethers formed by flowing neutrophils with single platelets, membrane tethers formed by neutrophils rolling on P-selectin were of longer length and longer duration (Fig. 7 and Fig. 8). These longer lengths and durations were not due to β2-integrin bonding since treatment of neutrophils with anti-CD18 did not inhibit tether formation. More likely they appear to be due to multiple binding interactions in the cell-surface contact area that would reduce the stress on the tether as well as the close proximity of the tether to the glass, which allowed multiple bonding of the tether to the absorbed P-selectin (as seen in Fig. 7 and Fig. 8).
During neutrophil tethering to P-selectin–coated surfaces, it appeared that detached membrane tethers were occasionally deposited on the surface. These deposited tethers may contain PSGL-1 and L-selectin to facilitate neutrophil (or platelet) interactions. Similarly, membrane tethers, if sufficiently long, may serve as a template for the formation of linear strings of neutrophils, a multicellular structure previously described by others (Alon et al. 1996; Walcheck et al. 1996; Lim et al. 1998). This tether-dependent mechanism of string formation would be distinct from neutrophil collision–assisted deposition via L-selectin, which would be expected to produce branched structures on the surface, not linear structures.
Adhesion of free-flowing neutrophils to activated endothelium or platelets is a key step in inflammation and thrombotic processes. The dynamics of selectin bonding determines whether a flowing neutrophil will adhere or detach. We present data that over 32% of neutrophil–platelet interactions under flow result in the formation of elongated membrane tethers. Similarly, we also demonstrated that neutrophils form elongated tethers when rolling on P-selectin–coated surfaces or platelet monolayers. The formation of these tethers is physiologically significant in that they shield the bond from full loading by changing the length and angle of the lever arm. Tether formation reduces the force on the bond by a factor of
2 (Shao et al. 1998) with an expected reduction of koff by a factor of
2 for Fb < 150 pN (Smith et al. 1999). Given the reduction of stress on the bond due to the tethers and the consequent enhancement of the cellular interaction time, these tethered neutrophils are the ones with the greatest likelihood of transitioning to firm arrest in vivo. In addition, these tethers also may provide a mechanism by which neutrophils can translate between gaps between platelets and remain on or near the surface in close proximity to localized activating agents. By directly visualizing the formation of membrane tethers by neutrophils as they interact with platelets and P-selectin–coated surfaces, we have confirmed a widely postulated structure in cell–cell adhesion. The formation of these structures influences the dynamics of cell rolling as well as its biomechanical analysis and may have important implications for the rolling and adhesion of neutrophils in vivo.
| Acknowledgments |
|---|
This work was supported by a National Institutes of Health grant (HL56621). Dr. D.W. Schmidtke is a postdoctoral fellow of the Southeastern Pennsylvania American Heart Association (grant no. 9920392U) and Dr. S.L. Diamond is an Established Investigator of the National American Heart Association (grant no. 99-40027).
Submitted: 26 June 1999
Revised: 7 March 2000
Accepted: 16 March 2000
Abbreviations used in this paper: DIC, differential interference microscopy; PSGL-1, P-selectin glycoprotein ligand 1.
| References |
|---|
|
|
|---|
Alon R. Hammer D.A. Springer T.A. Lifetime of the P-selectin carbohydrate bond and its response to tensile force in hydrodynamic flow, Nature., 374, 1995, 539–542.[Medline]
Alon R. Fuhlbrigge R.C. Finger E.B. Springer T.A.. Interactions through L-selectin between leukocytes and adherent leukocytes nucleate rolling adhesions on selectins and VCAM-1 in shear flow, J. Cell Biol., 135, 1996, 849–865.
Alon R. Chen S. Puri D.K. Finger E.B. Springer T.A.. The kinetics of L-selectin tethers and the mechanics of selectin-mediated rolling, J. Cell Biol., 138, 1997, 1169–1180.
Bahara P. Nash G.B.. Sparsely adherent platelets support capture and immobilization of flowing neutrophils, J. Lab. Clin. Med., 132, 1998, 223–228.[Medline]
Bell G.I.. Models for the specific adhesion of cells to cells, Science., 200, 1978, 618–627.
Bruehl R.E. Moore K.L. Lorant D.E. Borregaard N. Zimmerman G.A. McEver R.P. Bainton D.F.. Leukocyte activation induces surface redistribution of P-selectin glycoprotein ligand-1, J. Leuk. Biol., 61, 1997, 489–499.[Abstract]
Buttrum S.M. Hatton R. Nash G.B.. Selectin-mediated rolling of neutrophils on immobilized platelets, Blood., 82, 1993, 1165–1174.
Chen S.Q. Springer T.A.. An automatic braking system that stabilizes leukocyte rolling by an increase in selectin bond number with shear, J. Cell Biol., 144, 1999, 185–200.
Diacovo T.G. Roth S.J. Buccola J.M. Bainton D.F. Springer T.A.. Neutrophil rolling, arrest, and transmigration across activated, surface-adherent platelets via sequential action of P-selectin and the β2-integrin CD11b/CD18, Blood., 88, 1996, 146–157.
Evans S. Berk D. Leung A.. Detachment of agglutinin-bonded red blood cells. I. Forces to rupture molecular-point attachments, Biophys. J., 59, 1991, 838–848.[Medline]
Fritz J. Katopodis A.G. Kolbinger F. Anselmetti D.. Force-mediated kinetics of single P-selectin/ligand complexes observed by atomic force microscopy, Proc. Natl. Acad. Sci. USA, 95, 1998, 12283–12288.
Goldman A.J. Cox R.G. Brenner H.. Slow viscous motion of a sphere parallel to a plane wallcouette flow, Chem. Eng. Sci., 22, 1967, 653–660.
Hagberg I.A. Roald H.E. Lyberg T.. Adhesion of leukocytes to growing arterial thrombi, Thromb. Haemost, 80, 1998, 852–858.[Medline]
Hamburger S.A. McEver R.P.. GMP-140 mediates adhesion of stimulated platelets to neutrophils, Blood., 75, 1990, 550–554.
Kostantopoulos K. Grotta J.C. Sills C. Wu K.K. Hellums J.D.. Shear-induced platelet aggregation in normal subjects and stroke patients, Thromb. Haemost, 74, 1995, 1329–1334.[Medline]
Lalor P. Nash G.B.. Adhesion of flowing leucocytes to immobilized platelets, Br. J. Haematol., 89, 1995, 725–732.[Medline]
Lawrence M.B. Springer T.A.. Leukocytes roll on a selectin at physiologic flow ratesdistinction from and prerequisite for adhesion through integrins, Cell, 65, 1991, 859–873.[Medline]
Lawrence M.B. Kansas G.S. Kunkel E.J. Ley K.. Threshold levels of fluid shear promote leukocyte adhesion through selectins (CD62L,P,E), J. Cell Biol., 136, 1997, 711–727.
Lim Y.C. Snapp K. Kansas G.S. Camphausen R. Ding H. Luscinskas F.W.. Important contributions of P-selectin glycoprotein ligand-1-mediated secondary capture to human monocyte adhesion to P-selectin, E-selectin, and TNF-alpha-activated endothelium under flow in vitro, J. Immunol., 161, 1998, 2501–2508.
Mehta P. Cummings R.D. McEver R.P.. Affinity and kinetic analysis of P-selectin binding to P-selectin glycoprotein ligand-1, J. Biol. Chem., 273, 1998, 32506–32513.
Mickelson J.K. Lakkis N.M. Villarreal-Levy G. Hughes B.J. Smith C.W.. Leukocyte activation with platelet adhesion after coronary angioplastya mechanism for recurrent disease?, J. Am. Coll. Cardiol., 28, 1996, 345–353.[Abstract]
Moore K.L. Patel K.D. Bruehl R.E. Li F. Johnson D.A. Lichenstein H.S. Cummings R.D. Bainton D.F. McEver R.P.. P-selectin glycoprotein ligand-1 mediates rolling of human neutrophils on P-selectin, J. Cell Biol., 128, 1995, 661–671.
Neumann F.J. Marx N. Gawaz M. Brand K. Ott I. Rokitta C. Sticherling C. Meinl C. May A. Schömig A.. Induction of cytokine expression in leukocytes by binding of thrombin-stimulated platelets, Circulation., 95, 1997, 2387–2394.
Rinder C.S. Bonan J.L. Rinder H.M. Mathew J. Hines R. Smith B.R.. Cardiopulmonary bypass induces leukocyte-platelet adhesion, Blood., 79, 1992, 1201–1205.
Shao J.Y. Hochmuth R.M.. Micropipette suction for measuring piconewton forces of adhesion and tether formation from neutrophil membranes, Biophys. J., 71, 1996, 2892–2901.[Medline]
Shao J.Y. Hochmuth R.M.. Mechanical anchoring strength of L-selectin, β2 integrins, and CD45 to neutrophil cytoskeleton and membrane, Biophys. J., 77, 1999, 587–596.[Medline]
Shao J.Y. Ting-Beall H.P. Hochmuth R.M.. Static and dynamic lengths of neutrophil microvilli, Proc. Natl. Acad. Sci. USA., 95, 1998, 6797–6802.
Smith M.J. Berg E.L. Lawrence M.B.. A direct comparison of selectin-mediated transient, adhesive events using high temporal resolution, Biophys. J., 77, 1999, 3371–3383.[Medline]
Walcheck B. Moore K.L. McEver R.P. Kishimoto T.K.. Neutrophil-neutrophil interactions under hydrodynamic shear stress involve L-selectin and PSGL-1, J. Clin. Invest., 98, 1996, 1081–1087.[Medline]
Weber C. Springer T.A.. Neutrophil accumulation on activated, surface-adherent platelets in flow is mediated by interaction of Mac-1 with fibrinogen bound to
IIbβ3 and stimulated by platelet-activating factor, J. Clin. Invest., 100, 1997, 2085–2093.[Medline]
Yeo E.L. Sheppard J.A. Feuerstein J.A.. Role of P-selectin and leukocyte activation in polymorphonuclear cell adhesion to surface adherent activated platelets under physiologic shear conditions (an injury vessel wall model), Blood., 83, 1994, 2498–2507.
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|