Report |
Direct measurement of the lamellipodial protrusive force in a migrating cell
Correspondence to Manfred Radmacher: mr{at}biophysik.uni-bremen.de
|
|
|---|
There has been a great deal of interest in the mechanism of lamellipodial protrusion (Pollard, T., and G. Borisy. 2003. Cell. 112:453465). However, one of this mechanism's endpoints, the force of protrusion, has never been directly measured. We place an atomic force microscopy cantilever in the path of a migrating keratocyte. The deflection of the cantilever, which occurs over a period of
10 s, provides a direct measure of the force exerted by the lamellipodial leading edge. Stall forces are consistent with
100 polymerizing actin filaments per micrometer of the leading edge, each working as an elastic Brownian ratchet and generating a force of several piconewtons. However, the force-velocity curves obtained from this measurement, in which velocity drops sharply under very small loads, is not sensitive to low loading forces, and finally stalls rapidly at large loads, are not consistent with current theoretical models for the actin polymerization force. Rather, the curves indicate that the protrusive force generation is a complex multiphase process involving actin and adhesion dynamics.
| Introduction |
|---|
|
|
|---|
| Results and discussion |
|---|
|
|
|---|
40 nN, which is consistent with previous results on keratocytes using calibrated microneedles (Oliver et al., 1995).
|
|
140200 nm (Laurent et al., 2005). This corroborates the assertion that the contact length of the cantilever where it hits the lamellipod will be
3 µm; this is the long dimension of the cantilever at its base (Fig. 1 b).
Note that after the leading edge is stalled locally, the parts of the leading edge adjacent to the stalled region continue to advance and deform, and, on the scale of tens of seconds, the lamellipodial actin network undergoes significant remodeling so that the lamellipod "sneaks around" the cantilever. In
20 s, the cantilever hits the mound of the cell body and starts to deflect significantly (Fig. 2 and Video 2, available at http://www.jcb.org/cgi/content/full/jcb.200601159/DC1).
Three representative examples of the force versus time curves are given in Fig. 3 (a, c, and e). Because the cantilever is assumed to maintain contact with the protruding lamellipod, differentiating the position of the cantilever as a function of time gives the velocity of that portion of the lamellipod. This enables force-velocity relations to be plotted for each force-time curve as shown in Fig. 3 (b, d, and f). The mean stall force (where the cantilever movements stops, at least momentarily) is 1.18 ± 0.35 nN (SD; n = 12). Table I shows the variability in individual cells regarding stall force, initial cantilever velocity at the point where it contacts the cell, and velocity of the trailing edge of the cell at the moment the cantilever contacts the leading edge. These two velocities are uncorrelated, and neither of them is correlated with the stall force.
|
|
100 pN would cause deflections so small that they would be undetectable from the images). Chemically speaking, signaling material that accumulated on the cantilever does not appear to be a factor, as the velocity reduction effect is seen with both clean cantilevers and those used multiple times. Rather, the leading edge of the cell appears to slow down just before or at the initial instant of striking the cantilever. To ask when this reduction in lamellipodial velocity occurred, we used reflection interference contrast microscopy (RICM) in which close adhesions at the cell ventral surface and the cantilever as a stationary obstacle could be simultaneously visualized. To avoid pronounced reflections from the gold-coated cantilever, which obscures events when the cantilever is in close proximity to the leading edge, we used uncoated SiN cantilevers. This setup enabled us to observe that lamellipod slowdown occurs within typically
2 pixels (corresponding to 232 nm; n = 12) in front of the cantilever (Fig. 4 and Video 2).
If there is a narrow nonadherent rim of the leading edge that extends beyond the most anterior close contacts visualized by RICM (Lee and Jacobson, 1997), slowdown occurs even closer to the cantilever. At this juncture, we favor the idea that the cell mechanically senses the presence of the proximate cantilever and tunes the protrusion velocity and force generation mechanism accordingly (see the last two paragraphs of this section). However, remote sensing by the cell of chemical/electrochemical gradients on the tens of nanometerlength scale cannot be absolutely ruled out.
|
4 pN of force is generated per filament (the elastic Brownian ratchet model predicts
27 pN per filament; Mogilner and Oster, 1996), there must be
100 active filaments impinging on 1 µm of the leading edge. For comparison, V. Small estimates
120 filaments per micrometer from electron micrographs of the trout keratocyte leading edge (Small, V., personal communication). Abraham et al. (1999) have estimated the number of actin filaments in the fibroblast lamellipod to be
240 in a frontal area of 176 nm x 1 µm. If we assume that the area in contact with the cantilever is
200 nm x 3 µm, effective pressures caused by the actin polymerization at stall can be calculated. For keratocytes, the lamellipodial pressure is
2 nN/µm2 (2 kPa), whereas for fibroblasts, it is
10 nN/µm2 (10 kPa; Abraham et al., 1999). In comparison, the measured polymerization pressure for an actin comet tail modeling that in Listeria monocytogenes is
1 nN/µm2 (1 kPa; Marcy et al., 2004; Parekh et al., 2005).
Fig. 5 a shows force-velocity relationships normalized by the unloaded velocity and the stall force.
(Note that the initial sharp drop of velocity at forces of the order of
100 pN is not depicted). They indicate that at low force, the velocity is insensitive to the load, whereas at high loads, the velocity of the lamellipod decreases sharply similar in form to the recent measurement for in vitro L. monocytogeneslike actin networks (Parekh et al., 2005). The initial force-insensitive region is not caused by a geometric effect of a flat cantilever hitting a curved leading edge (the estimate in supplemental material shows that it would take only a second or so for the part of the cell not initially tangent to the cantilever to hit it, whereas the flat part of the force-velocity curve persists for 58 s; available at http://www.jcb.org/cgi/content/full/jcb.200601159/DC1).
|
There are several theoretical possibilities that could explain the observed force-velocity relation. The initial sharp drop of velocity at very small forces of tens of piconewtons per micrometer can be explained in the following ways: (1) weak adhesions at the leading edge that limit the polymerization rate and either slide (Jurado et al., 2005) or stop to assemble (Bohnet et al., 2006) at very small loads; (2) small osmotic/hydrostatic pressure at the leading edge (Charras et al., 2005); or (3) thermal membrane undulations that can be dampened by small loads (Mogilner and Oster, 1996). In principle, the first sharp drop of velocity could be explained by rapid recoil of the softer lamellipodial network when it encounters the stiffer cantilever. If this is the case, this part of the force-velocity relation is not a feature of the lamellipodial network but rather is a result of the measurement technique. These possibilities are discussed in detail in the supplemental material.
The insensitivity of the velocity to low loads and its sharp drop at a greater load can be the result of a few possibilities. (1) This could be the result of two sequential processes, one of which is force independent (for example, the chemical reactions associated with adhesion). In that case, at small loads, the force-limited process is much faster than the force-independent process, and the average duration of the step of protrusion is force independent. However, at a greater load, the force-limited process becomes slower than the force-independent one, and the average duration of the step of protrusion increases with the load. Several molecular motors (for example, RNA polymerase [Wang et al., 1998] and kinesin [Schnitzer et al., 2000]) and possibly myosin VI (Iwaki et al., 2006) have such force-velocity relations for this reason. (2) Another possibility is that a strong local osmotic/hydrostatic pressure (Charras et al., 2005) or gel swelling pressure (Herant et al., 2003) is the force-generating mechanism at the leading edge, in which case the velocity would not depend on the load until the pressure at the leading edge is overcome, and then actin polymerization is rapidly stalled, leading to a concave force-velocity relation. (3) Yet another possibility is the force-dependent reinforcement of the dendritic actin network by accelerated branching (Carlsson, 2003). (4) Finally, the elastic ratchet model can explain the concave force-velocity curve if actin filaments at the leading edge are short and rigid (Mogilner and Oster, 1996). To summarize, the stall force we measure agrees well with the elastic polymerization ratchet model, but the measured convex force-velocity relation poses a challenge to models of protrusion.
In vivo, the force-velocity curve, which was measured with an AFM cantilever as described above, results from an interdependent composite of multiple, possibly redundant mechanisms and limiting factors, including actin polymerization, local osmotic pressure, molecular motors, adhesion, and viscoelastic coupling to regions proximate to the cantilever, rather than a single process such as actin polymerization that can be isolated in in vitro systems (Marcy et al., 2004; Parekh et al., 2005). (This interdependence of factors can be seen by the fact that a weak shear flow of only
0.01 nN/µm acting on the leading edge of keratocytes, which is much less than what we measure as a stall force, can stop protrusion by probably interfering with nascent adhesions [Bohnet et al., 2006]). Also, in vivo, mechanical contact can trigger local mechanochemical pathways that generate signals, causing the delocalization of polymerization-maintaining complexes. Nevertheless, our results provide the first direct measurements of lamellipodial protrusion force characteristics of a crawling cell and, therefore, represent a mechanical benchmark against which the adequacy of our theoretical understanding of protrusion can be judged.
| Materials and methods |
|---|
|
|
|---|
5 min. All chemicals were purchased from Sigma-Aldrich or Biochrom. Experiments were usually performed within a few minutes after cells started to migrate. Cells were kept at 4°C until they were transferred to the optical microscopes, which were at room temperature.
Force measurement microscopy
A 200 x 200 x 20-µm piezostage (Physik Instrumente) was integrated into a thick aluminum plate that replaced the stage on an optical microscope (Axiovert 135 TV; Carl Zeiss MicroImaging, Inc.) such that a microscope slide with cells could be micropositioned in x, y, and z (Fig. S1, available at http://www.jcb.org/cgi/content/full/jcb.200601159/DC1). A second thick aluminum plate was placed on top of the Axiovert stage and supported by three adjustable points. An AFM cantilever (microlever obtained from Veeco Instruments) was mounted on a plexiglass holder and inserted in a recess of the second aluminum plate so that the cantilever was oriented perpendicular to the substrate (Fig. 1 a). The spring constant of the cantilevers was measured according to the thermal noise method (Butt and Jaschke, 1995) and was found to be in the range of 7 mN/m. To adjust the distance between the cantilever and microscope slide, the slide was oscillated in the y direction by driving the piezo with a sine function, and the cantilver was lowered so that it was in contact with the slide. Then the cantilever was retracted until its oscillation disappeared. To compensate for potential drift, we retracted the cantilever further by 80100 nm. This procedure was applied just before each measurement. Cells were positioned in front of the cantilever, and its deflection after cell contact was recorded with a CCD camera (4912-5100/0000; Cohu) and a videocassette recorder (TL300; Panasonic).
RICM
RICM was performed on the same Axiovert 135 TV optical microscope as the force measurement and with the same setup for holding the cantilever. A mercury lamp (HBO 50; Carl Zeiss MicroImaging, Inc.), an antiflex slider, and a 63x antiflex objective together with standard oil immersion objectives (n = 1.518; all components were purchased from Carl Zeiss MicroImaging, Inc.) were used. Cells were prepared on coverslips (Omnilab). The coverslips were attached with magnets to a stainless steel holder to allow free access from the top. In this series of experiments, uncoated cantilevers (MLCT-NONM; Veeco Instruments) were brought in contact with the glass slide and served as fixed obstacles. A green bandpass filter (D535/40; Chroma Technology Corp.) was used to avoid damage of the cells by UV light and to enhance contrast in the RICM image. The sequences were recorded with a 12-bit CCD camera (Retiga 4000R FAST Mono; QImaging) and transferred directly to a computer (MacIntosh G4; Apple) via fire wire.
Fluorescence and AFM
The cells were prepared for fluorescence as described previously (Lee and Jacobson, 1997). In brief,
500 µl of a mixture of 1.5 ml PBS, 0.5 ml of 0.1% Triton X-100 in PBS, 100 µl of 50% glutaraldehyde in water, and
100 µl of 100 µg/ml rhodamine-phalloidin in MeOH was introduced shortly after the lamellipod struck the cantilever. After
1 min of incubation with the fixation and staining mixture, cells were washed several times in PBS and imaged later with an Axiovert 135 TV microscope. Images were recorded with a Visicam (Visitron Systems) using CamWare 1.26 (PCO AG) and a PC operated with Windows 2000 SP4 (Microsoft). Contact-mode AFM on fixed and stained cells was performed on a microscope (MFP3D; Asylum Research).
Data acquisition and analysis
Force measurements were performed as follows: the recorded video frames were digitized with a frame grabber card (AG-5; Scion Corp.) using ImageJ 1.33u software (National Institutes of Health). The time period of interest (deflection of the cantilever by the lamellipod) was recorded in 768 x 512-pixel images at 25 frames/s. For each image, we averaged five neighboring horizontal lines, which were perpendicular to the cantilever. Because the cantilever is the brightest object in this line, the position of the edge could be defined by looking at a certain gray value. By following this position, we were able to determine the deflection as a function of time. Calibration was performed with a stage micrometer (100 lines per millimeter; Leitz) to generate deflection versus time graphs. These data sets contained a significant amount of noise and were smoothed by using a spline fit option of IGOR Pro (WaveMetrics). The smoothing factor was set to one, and the SD was varied to obtain the best fit. To produce force-velocity curves, the velocity of the tip was obtained by differentiating the smoothed position versus time curve, whereas the force was calculated from Hooke's Law. Velocity versus force curves were normalized by the initial velocity of the cantilever (vmax) and by the force at the point where v = vmax/2 (f1/2). Error bars for the force were calculated by using the SD of the deflection. Errors in velocity were not calculated because the position versus time data had to be smoothed before taking the derivative.
For AFM, height profiles were obtained after flattening height images with a second order flatten option, which is available in the IGOR software. The recording and analysis were performed with IGOR Pro. For RICM, the images were recorded with a 512 x 512-pixel array and an exposure time of 1 s. The position of the adhesions at the front of the lamellipod, as detected by RICM, were recorded from
30 s before cantilever contact to the last visible position of the leading edge (as a result of the high reflection of the cantilever). Using IGOR Pro, kymographs were constructed from the time series of images (Fig. 4, b and c) by extracting lines from the videos that capture the collision of the leading edge with the cantilever; spatial differentiation of such lines gave sharper edge detection. Calibration was performed with a stage micrometer.
Online supplemental material
Video 1 is a typical video of a trout keratocyte deflecting an AFM cantilever until the cell passes under the cantilever, which then springs back to its initial position. Video 2 is an RICM video showing cell movement before contact with the leading edge of a keratocyte, during initial contact, and during contact with the body of the cell. Fig. S1 is a schematic of the cantilever-positioning stage. Supplemental material provides data on the biophysics of possible force generation mechanisms. Online supplemental material is available at http://www.jcb.org/cgi/content/full/jcb.200601159/DC1.
| Acknowledgments |
|---|
Submitted: 27 January 2006
Accepted: 7 August 2006
| References |
|---|
|
|
|---|
Abraham, V.C., V. Krishnamurthi, D.L. Taylor, and F. Lanni. 1999. The actin-based nanomachine at the leading edge of migrating cells. Biophys. J. 77:17211732.[Medline]
Bohnet, S., R. Ananthakrishnan, A. Mogilner, J.-J. Meister, and A.B. Verkhovsky. 2006. Weak force stalls protrusion at the leading edge of the lamellipodium. Biophys. J. 90:18101820.[CrossRef][Medline]
Bray, D. 2001. Cell Movements: from Molecules to Motility. Garland Press, NY. 372 pp.
Butt, H.-J., and M. Jaschke. 1995. Calculation of thermal noise in atomic force microscopy. Nanotechnology. 6:17.[Medline]
Carlsson, A. 2003. Growth velocities of branched actin networks. Biophys. J. 84:29072918.[Medline]
Charras, G., J. Yarrow, M. Horton, L. Mahadevan, and T. Mitchison. 2005. Non- equilibration of hydrostatic pressure in blebbing cells. Nature. 435:365369.[CrossRef][Medline]
Condeelis, J. 1993. Life at the leading edge: the formation of cell protrusions. Annu. Rev. Cell Biol. 9:411444.[CrossRef][Medline]
Dickinson, R., L. Caro, and D. Purich. 2004. Force generation by cytoskeletal filament end-tracking proteins. Biophys. J. 87:28382854.[CrossRef][Medline]
Felder, S., and E.L. Elson. 1990. Mechanics of fibroblast locomotion: quantitative analysis of forces and motions at the leading lamellas of fibroblasts. J. Cell Biol. 111:25132526.
Herant, M., W. Marganski, and M. Dembo. 2003. The mechanics of neutrophils: synthetic modeling of three experiments. Biophys. J. 84:33893413.[Medline]
Iwaki, M., H. Tanaka, A.H. Iwane, E. Katayama, M. Ikebe, and T. Yanagida. 2006. Cargo-binding makes a wild-type single-headed myosin-VI move processively. Biophys. J. 90:36433652.[CrossRef][Medline]
Jurado, C., J.R. Haserick, and J. Lee. 2005. Slipping or gripping? Fluorescent speckle microscopy in fish keratocytes reveals two different mechanisms for generating a retrograde flow of actin. Mol. Biol. Cell. 16:507518.
Ladam, G., L. Vonna, and E. Sackmann. 2005. Protrusion force transmission of amoeboid cells crawling on soft biological tissue. Acta Biomater. 1:485497.[CrossRef][Medline]
Lauffenburger, D.A., and A.F. Horwitz. 1996. Cell migration: a physically integrated molecular process. Cell. 84:359369.[CrossRef][Medline]
Laurent, V., S. Kasas, A. Yersin, T. Schaffer, S. Catsicas, G. Dietler, A. Verkhovsky, and J. Meister. 2005. Gradient of rigidity in the lamellipodia of migrating cells revealed by atomic force microscopy. Biophys. J. 89:667675.[CrossRef][Medline]
Lee, J., and K. Jacobson. 1997. The composition and dynamics of cell-substratum adhesions in locomoting fish keratocytes. J. Cell Sci. 110:28332844.[Abstract]
Marcy, Y., J. Prost, M. Carlier, and C. Sykes. 2004. Forces generated during actin-based propulsion: a direct measurement by micromanipulation. Proc. Natl. Acad. Sci. USA. 101:59925997.
McGrath, J., N. Eungdamrong, C. Fisher, F. Peng, L. Mahadevan, T. Mitchison, and S. Kuo. 2003. The force-velocity relationship for the actin-based motility of Listeria. Curr. Biol. 13:329332.[CrossRef][Medline]
Mogilner, A., and G. Oster. 1996. Cell motility driven by actin polymerization. Biophys. J. 71:30303045.[Medline]
Mogilner, A., and G. Oster. 2003. Force generation by actin polymerization II: the elastic ratchet and tethered filaments. Biophys. J. 84:15911605.[Medline]
Oliver, T., M. Dembo, and K. Jacobson. 1995. Traction forces in locomoting cells. Cell Motil. Cytoskeleton. 31:225240.[CrossRef][Medline]
Parekh, S., O. Chaudhuri, J. Theriot, and D. Fletcher. 2005. Loading history determines the velocity of actin-network growth. Nat. Cell Biol. 7:12191223. (published erratum appears in Nat. Cell Biol. 2006. 8:100).[Medline]
Pollard, T., and G. Borisy. 2003. Cellular motility driven by assembly and disassembly of actin filaments. Cell. 112:453465.[CrossRef][Medline]
Ridley, A., M.A. Schwartz, K. Burridge, R.A. Firtel, M.H. Ginsberg, G. Borisy, J.T. Parsons, and A.R. Horwitz. 2003. Cell migration: integrating signals from front to back. Science. 302:17041709.
Schnitzer, M.J., K. Visscher, and S.M. Block. 2000. Force production by single kinesin motors. Nat. Cell Biol. 2:718723.[CrossRef][Medline]
Small, J., T. Stradal, E. Vignal, and K. Rottner. 2002. The lamellipodium: where motility begins. Trends Cell Biol. 12:112120.[CrossRef][Medline]
Wang, M.D., M.J. Schnitzer, H. Yin, R. Landick, J. Gelles, and S.M. Block. 1998. Force and velocity measured for single molecules of RNA polymerase. Science. 282:902907.
Wiesner, S., E. Helfer, D. Difry, G. Ducouret, F. Lafuma, M. Carlier, and D. Pantaloni. 2003. A biomimetic motility assay provides insight into the mechanism of actin-based motility. J. Cell Biol. 160:387398.
This article has been cited by other articles:
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|